Model: BMW 750Li 2006

All operation (ready) for ecu programming:

Part 1 – connection issues

Step 1 – connection to voltage supply

Connect the car to a stable voltage supply

Make sure the battery clamps are properly fixed

Fully charge Autel MS908P tablet

Step 2 – connection to network

Connect Maxisys pro to the Internet

Make sure the network connection is stable to ensure a successful ECU programming

Both wired & wireless connection is ok, using ethernet cable

Check the connection status icon to confirm the internet connection is successful

Step 3 – connection to J2534 ecu programmer

Connect Maxiflash J2534 ECU programming device to MS908P using USB cable

Tighten the screws

Step 4 – connection to the car

Connect Maxisys pro to the vehicle with OBDii cable

Now, all connection complete

Part 2 – ECU programming

Here goes the ECU programming on BMW.

Select Diagnostics n the main menu of Maxisys pro MS908P

Select BMW

Turn ignition off…wait 10 seconds…turn ignition on

Tap OK and read out vehicle data

Tap CIP (coding, individualizing and programming) for ecu programming

Vehicle configuration

Read data and tap ok to go on. Edit button is available to perform customized SA configuration

Make sure and delete vehicle data correctly

Tap ok

Upon completion, tap ESC to exit

Tap yes to save revised data

Maxisys is communicating with control units for a few minutes

Confirm whether any control unit has been replaced or not before programming

Tap yes or no accordingly to continue

Select SIM for coding/programming

Tap Selective update to reprogram a specific control module separately

Or perform Complete update by selecting all modules

Here, program SIM only

Tap OK for vehicle info

Tap Execute measures plan to continue

Turn off ignition

Switch on terminal 15 (ignition)

Again, make sure of the stable network connection, and other connections to start reflashing

Coded! Stored DTCs will be cleared

Turn off ignition and remove the key with remote control from key slot (if provided).

Wait 10 seconds.

Insert the key with remote control and turn on ignition

Then go on the next action. All action will be done one by one automatically

Do not perform other tasks at the same time

The system will generate a report after reflashing